ETERMINATION OF THE OPTIMUM CONDITIONS FOR SILVER RECOVERY FROM PHOTOGRAPHIC FIXER IN SOME STATE SYRIAN HOSPITALS AND PRIVATE CLINICS

  • 07 Sep 2009
  • Published Resarch - Pharmacy

Researchers

Abdulalah T. Mohammed, Mazen Ragab, Ibaa Chikh Al-Ard, Jamal Darwishah, Nour Al-Habal

Published in

Journal of university of Anbar for Pure science, Volume 3, Issue 3, 2009


Abstract

A low cost metal replacement method has been used to determine the optimum conditions for silver recovery in photographic fixer received from different clinics. The chosen experimental parameters and their range were (i) pH 3- 5, (ii) reaction time 1-7 days, (iii) different metals and metal alloys and (iv) suitable acid at concentration 10% (in weight). The silver concentration in the manageable fixer solution should be ≤ 5 mg/ L. The method by using these optimum conditions is particularly suited for treating the fixer solution in a manner which enables to considerable reduction in cost of silver recovery and reduced environmental pollution.

Link to read full paper

https://www.iasj.net/iasj?func=fulltext&aId=15620